Abstract

Objective: To propose a method to judge the safety of axial pedicle screw placement based on the position of the tip of the screw trajectory on the anteroposterior and lateral X-ray radiographs. Methods: The cervical CT data of 40 patients admitted to the Second Affiliated Hospital of Wenzhou Medical University from December 2020 to December 2021 were selected, including 24 males and 16 females, with a mean age of (47.6±13.2) years. Based on the three-dimensional model reconstruction of Mimics software and its function of X-ray, the transmission of the axial pedicle screw and its anteroposterior and lateral films was simulated. The position of the tip of the simulated screw trajectory was divided into 5 regions (regions Ⅰ-Ⅴ) from the inside to the outside on the anteroposterior virtual radiographs, and the upper and lower regions (regions a, b) on the lateral virtual radiographs. By adjusting the direction of the screw, the tip of the screw was located in the corresponding 10 regions (80 screws in each area) on the virtual projections of the anteroposterior and lateral virtual radiographs respectively, and its accuracy was analyzed by CT to determine whether each screw penetrated the medial wall of the pedicle or vertebral artery foramen. The anteroposterior and lateral X-rays and postoperative CT data of 34 patients who underwent axial pedicle screw placement (67 axial pedicle screws were placed in total) from January 2014 to December 2021 were collected, including 18 males and 16 females, with a mean age of (45.8±14.1) years. The position of the tip of the screw trajectory on the anteroposterior and lateral films was divided in the same way. The number of screws in the corresponding 10 positions was counted, and CT analysis was used to determine whether each screw penetrated the medial wall of the axial pedicle or the vertebral artery foreman. Results: The results of the imaging simulation screw placement study showed that the perforation rate of the vertebral artery foramen in region Ⅳ and Ⅴ was 75.0% (120/160) and 100% (160/160), respectively, while the perforation rate of the medial wall of the axial pedicle in the region Ⅰ was 85.6%(137/160). The failure rate in regions Ⅱ and Ⅲ was relatively lower, and the performance of simulated screws located in the region a was better than those in region b. The perforation rates of the medial wall in regions (a-Ⅱ) and (a-Ⅲ) was 7.5% (6/80) and 0 (0/80), respectively, and the perforation rates of the vertebral foramen was 0 (0/80) and 21.3% (17/80), respectively. The retrospective imaging study also showed a higher rate of placement failure in regions Ⅰ, Ⅳ and Ⅴ, and relatively lower in regions Ⅱ and Ⅲ. There were total of 15 screws in region a-Ⅱ and a-Ⅲ, and no destruction of the medial wall of the axial pedicle and the vertebral artery foreman occurred there. Conclusions: Regions a-Ⅱ and a-Ⅲ are the "safety areas" of the tip of the pedicle screw trajectory in the axial vertebra. By analyzing the tip of the pedicle screw trajectory on the anteroposterior and lateral radiographs, the operator can determine the reasonable trajectory of axial pedicle screw placement, prevent the injury of the cervical spinal cord and vertebral artery, and reduce the risk of operation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call