Abstract

BackgroundAlthough x-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. Therefore, in this work, a reader study on nine post-mortem human chest x-ray dark-field radiographs was performed to evaluate dark-field signal strength in the lungs, intraobserver and interobserver agreement, and image quality and to correlate with findings of conventional x-ray and CT.MethodsIn this prospective work, chest x-ray dark-field radiography with a tube voltage of 70 kVp was performed post-mortem on nine humans (3 females, 6 males, age range 52–88 years). Visual quantification of dark-field and transmission signals in the lungs was performed by three radiologists. Results were compared to findings on conventional x-rays and 256-slice computed tomography. Image quality was evaluated. For ordinal data, median, range, and dot plots with medians and 95% confidence intervals are presented; intraobserver and interobserver agreement were determined using weighted Cohen κ.ResultsDark-field signal grading showed significant differences between upper and middle (p = 0.004–0.016, readers 1–3) as well as upper and lower zones (p = 0.004–0.016, readers 1–2). Median transmission grading was indifferent between all lung regions. Intraobserver and interobserver agreements were substantial to almost perfect for grading of both dark-field (κ = 0.793–0.971 and κ = 0.828–0.893) and transmission images (κ = 0.790–0.918 and κ = 0.700–0.772). Pulmonary infiltrates correlated with areas of reduced dark-field signal. Image quality was rated good for dark-field images.ConclusionsChest x-ray dark-field images provide information of the lungs complementary to conventional x-ray and allow reliable visual quantification of dark-field signal strength.

Highlights

  • X-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs

  • The discovery of x radiation marks the birth of diagnostic radiology and its use remains indispensable in daily clinical practice

  • Visual grading of dark-field and transmission signals Statistical analysis of the dark-field and transmission gradings (Table 1) indicated a significant association between the lung zones and dark-field signal, which was further investigated by pairwise comparisons of regions of each lung for each reader (Fig. 2)

Read more

Summary

Introduction

X-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. X-rays can be Fingerle et al European Radiology Experimental (2019) 3:25 interpreted as particles, and show wave-like properties, such as refraction, that can be utilised for contrast formation [1, 2]. Grating-based x-ray dark-field imaging allows detection, quantification, and visualisation of small-angle x-ray scattering [5], which is not possible with conventional x-ray imaging devices. This technique has been translated to the use of conventional x-ray sources [6]

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)