Abstract

We present an imaginary part-based correlation mapping optical coherence tomography (IMcmOCT) technique for in vivo blood vessels imaging. In the conventional correlation mapping optical coherence tomography (cmOCT) method, two adjacent frames of intensity-based structural images are correlated to extract blood flow information and the size of correlation window has to be increased to improve the signal-to-noise ratio of microcirculation maps, which may cause image blur and miss the small blood vessels. In the IMcmOCT method, the imaginary part of a depth-resolved complex analytic signal in two adjacent B-scans is correlated to reconstruct microcirculation maps. Both phantom and in vivo experiments were implemented to demonstrate that the proposed method can provide improved sensitivity for extracting blood flow information in small vessels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.