Abstract

To compare image quality of magnetic resonance arthrography (MRA) of the hip with intra-articular injection of high-viscosity hyaluronic acid (HA-MRA) versus Gd-based contrast agent (Gd-MRA) in patients with femoroacetabular impingement (FAI). Design: single-centre, observational, retrospective, inter-individual, and cross-sectional. FAI patients who underwent HA-MRA (3mL of high-viscosity HA plus 17mL of saline) were compared with 37 age- and sex-matched FAI patients who underwent Gd-MRA (20mL of 2mmol/L solution of gadopentetate dimeglumine). Two independent blinded radiologists assessed image quality for all sequences (two-dimensional proton density, non-fat-sat axial, fat-sat coronal and sagittal; three-dimensional dual-echo steady state), using a 5-point Likert scale considering separately labrum, cartilage, round ligament, transverse ligament, and capsule. Pearson χ2 and Cohen κ were used. The HA-MRA group was composed of 37 patients (23 males, 14 females; median age 38years), the Gd-MRA group of 37 patients (21 males, 16 females; median age 38years), without significant difference for age (p = 0.937) and sex (p = 0.636). Image quality did not differ between the two readers for any structure: labrum (p ≥ 0.340), cartilage (p ≥ 0.198), round ligament (p ≥ 0.255), transverse ligament (p ≥ 0.806), and capsule (p ≥ 0.314). Inter-reader agreement (κ) ranged from 0.785 to 1.000. HA-MRA provided an image quality not significantly different from that of Gd-MRA. This may open the possibility of combining MRA and viscosupplementation in one single procedure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call