Abstract

An 86 year old man with a previous endovascular aortic repair presented with a type Ia endoleak five years after his intervention. Proximal extension with a custom made branched endograft with four inner branches was planned (E-xtra DESIGN MultiBranch; Jotec, Cryolife, Kennesaw, GA, USA). The 24 F graft was introduced using a through and through wire with significant resistance. (A) Upon retrieval of the introducer, there was complete avulsion of the left external iliac artery. (B) A 12 mm occlusion balloon was rapidly placed in the left iliac limb while the endovascular repair continued. Finally, an iliofemoral bypass was performed.Image 1

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.