Abstract

To validate a new sonographic technique for the display and measurement of fetal iliac crest angle (ICA), and to determine the relative contribution of standardized fetal pelvic measurements for estimating risk of Down syndrome during the second trimester of pregnancy. Three-dimensional ultrasonography of the fetal pelvis was performed during a second-trimester scan for genetic amniocentesis. A coronal view of the 'virtual pelvis' was obtained by applying a maximum intensity projection algorithm to visualize both iliac wings. Two different ICAs were measured from a coronal projection of the fetal pelvis (ICA-coronal 1 and ICA-coronal 2); the latter approach relied on using ischial tuberosities as reference landmarks. Next, a coronal projection of the fetal pelvis was rotated to demonstrate a rendered view of the axial fetal pelvis. Axial inner (ICA-inner), middle (ICA-middle) and outer (ICA-outer) ICAs were measured. The maximum anterior iliac distance measurement was defined as the widest separation between the most anterior points of the rendered iliac crests. The reproducibility of each ICA method was analyzed using Bland-Altman statistics. Simple and multiple logistic regression analysis determined the relative contribution of each parameter as a prenatal predictor of Down syndrome. Ninety-four normal fetuses and 19 fetuses with Down syndrome were examined. The ICA-middle and ICA-coronal 2 parameters were the most reproducible angle measurements. The mean +/- SD ICA-middle measurement for fetuses with Down syndrome was significantly greater than that for normal subjects (94.5 +/- 9.8 degrees vs. 83.1 +/- 6.5 degrees ; P < 0.001). The mean +/- SD ICA-coronal 2 angle measurement for fetuses with Down syndrome was slightly greater than that for normal subjects (57.9 +/- 5.5 degrees vs. 51.9 +/- 7.1 degrees ; P = 0.0014). A multiple logistic regression model including ICA-middle and ICA-coronal 2 provided a predictive ability of 88.1% based on the area under the receiver-operating characteristics curve. This combination had a sensitivity of 94.4% for a false-positive rate of 5% in the detection of Down syndrome. Standardized iliac crest measurements of the fetal pelvis can be used to identify some fetuses at risk for trisomy 21 during the second trimester of pregnancy.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.