Abstract
The gaseous oxygen pneumatic impact test is used to evaluate the suitability of nonmetallic materials for use in high-pressure oxygen systems. The test was evaluated by testing the reactivity of four materials over a range of impact pressures. The evaluation also investigated the effect of valve opening time and other test variables on the frequency of reaction. The variability of the data obtained for each test material was too large for the test method to be capable of distinguishing other than gross differences in the reactivity of materials. No relation was found between this variability and changes in valve opening time and other test variables. The materials studied were found to be unacceptable for use as reference standards. Because of the high variability of the test data, it is recommended that new methods be developed for evaluating the suitability of materials for use in high-pressure oxygen systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.