Abstract This contribution is aimed to compare the values of the ignition activation energies of two types of polyamide – Slovamid 6 FRB and Slovamid GF 50 LTS. Samples were isothermally stressed at five different temperatures between 500 °C a 550 °C, while the time to initiation of the flame combustion was monitored. Subsequently from the measured times were compiled Arrhenius plots under which activation energy of ignition of both polymers were calculated. The values of activation energies were 106 kJ.mol−1 and 158.0 kJ.mol−1 for Slovamid 6 FRB 4 and Slovamid 6 GF 50 LTS.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS of the VŠB – Technical University of Ostrava, Safety Engineering Series
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.