Abstract

This paper discusses the IEEE 1588 implementation with Frequency Locked Loop (FLL) and Phase Locked Loop (PLL). The work was supported by a Telecom technology provider; the objective is to study the feasibility of IEEE 1588 in the Base Stations (BSs) synchronization, on the basis of minimum structure changes. In order to meet the requirements of the mobile communication systems, IEEE 1588 was implemented using two different methods - the FLL and PLL. Based on the synchronization result, it is observed that the FLL method shows over adjustments when the network Packet Delay Variation (PDV) is large while the PLL method is likely to be affected by the amount of traffic from the master to the slave clock. Additionally, it is also observed that the overdamped PLL gives high frequency accuracy, but also amplifies the effect of PDV, resulting in a larger frequency instability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.