Abstract

Background: Iatrogenic hypoglycemia is an important complication for patients with diabetes. To detect a risk of hypoglycemia accurately during hospitalization, increasing accuracy of continuous glucose monitor (CGM) is necessary. Aim: We examined differences in calibration accuracy between point of care devices and “glucometers that were compliant with ISO15197:2013” (ISO compliant glucometers) when using personal CGM during hospitalization. Method: This was a prospective study where personal-CGM (GUARDIAN CONNECT) was worn for 6 days (CGM attachment: day 1) and blood glucose levels used to calibrate were obtained using point of care devices (StatStrip Xpress Glucose/Ketone) or ISO compliant glucometers (ACCU-CHEK Guide) using a randomized crossover design. Sixteen inpatients with type 2 diabetes were equally allocated to 2 groups. Point of care devices provided 11 blood glucose levels used to calibrate during days 2-3 and ISO compliant glucometers provided 11 blood glucose levels used to calibrate during days 4-5 in group 1. ISO compliant glucometers provided 11 blood glucose levels used to calibrate during days 2-3 and point of care devices provided 11 blood glucose levels used to calibrate during days 4-5 in group 2. In each group 1 and group 2, point of care devices and ISO compliant glucometers were allocated from “fixed 2 point of care devices” and “fixed 2 ISO compliant glucometers” using a randomized quadruple (2 × 2) crossover design. Mean absolute relative difference (MARD) was calculated for every calibration. Results: Blood glucose levels used to calibrate obtained using point of care devices was significantly higher than blood glucose levels used to calibrate obtained using ISO compliant glucometers (173.6 ± 69.9 mg/dL vs. 158.2 ± 47.9 mg/dL, p = 0.02: unpaired t-test). MARD was significantly higher on calibration using point of care devices than on calibration using ISO compliant glucometers (7.6 ± 7.5% vs. 5.8 ± 5.8%, p = 0.01: unpaired t-test). The study patients correlated to distributions of MARD on calibration using point of care devices (η2 = 0.19, p = 0.003: correlation ratio). The study patients also correlated to distributions of MARD on calibration using ISO compliant glucometers (η2 = 0.23, p < 0.001: correlation ratio). Discussion: StatStrip Xpress Glucose/Ketone is cheaper than other point of care devices in Japan, therefore, StatStrip Xpress Glucose/Ketone should be thought to be superior in terms of being able to measure the wide range of glucose levels (10–900 mg/dL) cheaply. ISO compliant glucometers may calibrate personal CGM more accurate than StatStrip Xpress Glucose/Ketone during hospitalization. The correlation between study patients and distributions of MARD may suggest the individual differences in CGM sensor accuracy between patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call