Abstract
Advances in the treatment of pediatric congenital heart disease have increased survival rates. Despite efforts to prevent neurological injury, many patients suffer from impaired neurodevelopmental outcomes. Compromised cerebral autoregulation can increase the risk of brain injury following pediatric cardiac surgery with cardiopulmonary bypass. Monitoring autoregulation and maintaining adequate cerebral blood flow can help prevent neurological injury. Our objective was to evaluate autoregulation parameters and to define the optimal blood pressure as well as the lower and upper blood pressure limits of autoregulation. Autoregulation was monitored prospectively in 36 infants after cardiopulmonary bypass surgery for congenital heart defects between January and December 2019. Autoregulation indices were calculated by correlating invasive arterial blood pressure, cortical oxygen saturation, and relative tissue hemoglobin levels with near-infrared spectroscopy parameters. The mean patient age was 4.1 ± 2.8months, and the mean patient weight was 5.2 ± 1.8kg. Optimal mean arterial pressure could be identified in 88.9% of patients via the hemoglobin volume index and in 91.7% of patients via the cerebral oxygenation index, and a lower limit of autoregulation could be found in 66.7% and 63.9% of patients, respectively. No significant changes in autoregulation indices at the beginning or end of the monitoring period were observed. In 76.5% ± 11.1% and 83.8% ± 9.9% of the 8 and 16 h monitoring times, respectively, the mean blood pressure was inside the range of intact autoregulation (below in 21.5% ± 25.4% and 11.3% ± 16.5% and above in 8.7% ± 10.4% and 6.0% ± 11.0%, respectively). The mean optimal blood pressure was 57.4 ± 8.7 mmHg and 58.2 ± 7.9 mmHg and the mean lower limit of autoregulation was 48.8 ± 8.3 mmHg and 45.5 ± 6.7 mmHg when generated via the hemoglobin volume index and cerebral oxygenation index, respectively. Postoperative noninvasive autoregulation monitoring after cardiac surgery in children can be reliably and safely performed using the hemoglobin volume index and cerebral oxygenation index and provides robust data. This monitoring can be used to identify individual hemodynamic targets to optimize autoregulation, which differs from those recommended in the literature. Further evaluation of this subject is needed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.