Abstract
Ezetimibe, which selectively inhibits cholesterol absorption across the intestinal wall and is used as an antihyperlipidemic agent, is synthesized for commercial use as a drug substance in highly pure form. During the synthetic process development studies of ezetimibe, an impurity was detected in the final product at levels ranging from 0.05% to 0.15% in reverse phase gradient high performance liquid chromatography (HPLC) method and its molecular weight was determined by LC–MS analysis. The impurity was identified as (3R,4S)-3-((S)-3-(4-fluorophenyl)-3-hydroxypropyl)-4-(4-hydroxyphenyl)-1-phenylazetidin-2-one which is called desfluoro ezetimibe (lactam-related) impurity, synthesized and characterized, the mechanism of its formation was discussed in detail. After all standardization procedures, it was used as a reference standard during validation of HPLC method and routine analyses. In addition, content of Eze-1 desfluoro impurity in Eze-1 intermediates was specified as 0.10% to keep the formation of desfluoro ezetimibe impurity under control and the related substances HPLC method was validated accordingly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.