Abstract
Using temperature measurement to provide insight into the health condition of an electrical machine at any operating point could be possible if a baseline temperature of the machine could be modelled in real-time and compared to the actual current temperature. In this study, transfer functions are being identified to be used as a baseline temperature response model for a small DC machine. As a preliminary study, the transfer functions are identified using experimental data of temperature responses at several no-load speed step inputs. The order of transfer function tested was between a range from 0 to 4. The third order transfer function was found to be the best followed by the first order transfer function with a model MSE error of less than 0.41 and 0.65 respectively. The slight variation on the poles of the system indicates that the thermal system of the electrical machine does not obey exactly the LTI hypothesis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.