Abstract
Introduction. Endurance exercise performance progressively deteriorates as the surrounding ambient temperature increases, 1 which is exacerbated when combined with increasing humidity 2 and solar radiation. 3 It is clear that there is a strong link between increases in thermoregulatory strain, due to elevations in both metabolic and ambient heat, and impaired endurance performance. 4 It has become commonplace to implement pre-cooling prior to competition to alleviate this performance decline, with ~50% of athletes having a defined strategy prior to competing in the heat. 5 Such strategies include the use of ice-vests, which have been suggested to improve time trial performance in the heat by approximately 5%. 6 However, little is known about the ambient temperature threshold above which pre-cooling becomes an effective strategy for enhancing endurance performance. With most studies focusing on a single ambient temperature, typically above 30EsC or a Wet Globe Bulb Temperature (WGBT) of 26EsC. 7 Therefore, it was the aim of this study to investigate the effect of pre-cooling in different environmental temperatures on time trial performance. It was hypothesized that pre-cooling would improve time trial performance in all environmental temperatures, with the magnitude of effect dependent on environmental temperature. Methods. In an independent groups design, 24 trained male cyclists (age 24.3 ± 5.1 years; VO 2max 61.3 ± 3.7 mL . kg . min -` ; training frequency ≥3 times per week) completed two time trials with (COLD) and without (CON) of pre-cooling using an ice-vest and sleeves ensemble. Pre-cooling was implemented for 30 minutes at rest and during a 9 minute progressive warm up, in ambient temperatures of 24.0 ± 0.1°C & 49.5 ± 1.4% rh (WBGT 19.2°C); 27.2 ± 0.3°C & 50.7 ± 5.3% rh (WBGT 22.1°C); or 35.0 ± 0.4°C & 50.6% ± 1.3% rh (29.2°C). Participants removed the cooling vest (if warn) on completion of the warm up, prior to completing a self-paced time trial designed to last ~60 minutes when ridden at ~75% W max . Results. Time trial performance was 6.2% and 2.6% faster following COLD in both 35EsC and 27EsC (figure 1A) but not 24EsC (1.2%). Magnitude based inferential statistics indicate that COLD was very likely beneficial to performance in 35EsC and likely beneficial in 27EsC and possibly beneficial in 24°C. Mean power was 2.4% 2.5% and 5.6% higher following COLD (figure 1B,C) and considered to be likely beneficial in 24°C and very likely beneficial in 27EsC and 35EsC. There was no effect of COLD on gastrointestinal temperature at any point. Conclusions. Pre-cooling with an ice-vest and sleeves is likely to have a positive effect on time trial performance at temperatures above 24EsC, with a clear relationship between ambient temperature and the magnitude of effect of pre-cooling. These results indicate that cyclists should start to consider implementing a pre-cooling procedure prior to racing a time-trial in environmental temperatures of 24EsC and above. Importantly, utilising pre-cooling in lower ambient temperatures is unlikely to have a detrimental effect on performance at the cooling intensities used here. To the authors’ knowledge, this is the first time that a lower ambient temperature threshold has been identified above which pre-cooling has a significant ergogenic impact on performance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.