Abstract

BACKGROUND: Palpation has been shown to be inaccurate at identifying lumbar interspinous spaces. Our goal in this study was to compare ultrasound imaging of the region to palpation. METHODS: Using ultrasound in the postpartum period, we estimated the interspinous level used for obstetric neuraxial anesthesia in 121 women and compared this estimation with the level estimated by palpation and documented in the chart by the anesthesiologist. RESULTS: In 67 of 121 (55%) patients, the vertebral level of the puncture mark documented by the treating anesthesiologist was in agreement with vertebral level as assessed using ultrasound, and in 39 (32%) women, the skin puncture level was estimated by ultrasound to be at least one interspace higher. The unweighted kappa was 0.08 (95% confidence interval: 0.02, 0.14). CONCLUSIONS: There was poor agreement between palpation and ultrasound estimation of the specific lumbar interspace, and when there was disagreement, the ultrasound estimate was more often higher than the palpitation estimate. (Anesth Analg 2008;106:538‐40)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.