Abstract

The aims of this study were to identify the location of the A1 pulley combining palpation technique with superficial palm landmarks and to determine the efficacy and safety of A1 pulley percutaneous release with a 19-gauge needle. Fourteen fresh frozen cadaveric specimens were used: 56 fingers and 14 thumbs. The location of the A1 pulley was based on anatomical landmarks and was identified in all digits. Complete release of the A1 pulley occurred in 60 of the 70 digits (85.7%). The length of the A1 pulley in thumbs was 5.7 mm and in other fingers 4.5 mm. There were no signs of neurovascular bundle injuries. The mean distance between needle pathway and neurovascular bundle was 4.3 mm in the thumbs and 6.5 mm in the other fingers. There were no total flexor tendon injuries. The location of the A1 pulley can be predicted with success. Percutaneous release of the A1 pulley with a 19-gauge needle shows acceptable results in both safety and efficacy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call