Abstract

ABSTRACT Reducing the power consumption of oil production wells is one of the important directions of oil industry development in the context of transition of many fields to the late stages of operation. At the same time, there is often a need to limit hydrocarbon production, which is often accomplished by shutting down wells completely. In this paper, the authors propose an approach to improve the energy efficiency of the electric centrifugal pump unit through the use of periodic operation mode, which allows to reduce the specific power consumption of the electric centrifugal pump unit. Also, this mode can be considered as a way to regulate the well flow rate. According to the results of calculations it was obtained that the reduction of specific power consumption of the unit when operating at nominal frequency can reach 5% relative to the continuous mode of operation. An assessment was made of the effect of reducing the frequency of the supply voltage in a periodic mode on the parameters of the operation of the installation and it was found that the well flow rate increased by 1.43% with a reduction in specific power consumption by 1.64%.