Abstract
Damping is an important property in predicting the response of any civil or mechanical engineering structure, including railway catenary systems. Numerical models describing the pantograph–catenary interaction are dependent on a proper description of the structural damping for both systems to obtain accurate results. A proper description of the damping in different pantographs can easily be found in the literature. However, few studies have considered the damping properties in railway catenary systems even though such systems are considered to be lightly damped. The aim of this study was to identify the system damping of catenary sections by thoroughly analyse several recorded acceleration time series. These time series were sampled in several points on three different existing railway catenary systems, rendering a good description of the system damping in the frequency range of 0–20Hz. The covariance-driven stochastic subspace identification (Cov-SSI) method was used to analyse the time series, and Rayleigh coefficients were successfully identified for all three catenary sections.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.