Abstract

To identify neonates at risk of haemolytic hyperbilirubinaemia through near-concurrent measurements of total serum/plasma bilirubin (TB) or transcutaneous bilirubin (TcB) and end-tidal breath carbon monoxide (CO), corrected for ambient CO (ETCOc), an index of bilirubin production and haemolysis. Paired TB/TcB (mg/dL) and ETCOc (ppm) measurements were obtained in newborns (n = 283) at 20 to <60 hours of age in five nurseries. TB/TcB values were assigned TB/TcB percentile risk values using the Bhutani hour-specific nomogram. In infants having two serial TB/TcB measurements (n = 76), TB rate of rise (ROR, mg/dL/h) was calculated. For the entire cohort (n = 283), 67.1% and 32.9% had TB/TcB<75th and ≥75th percentile, respectively. TB/TcB (5.79 ± 1.84 vs 9.14 ± 2.25 mg/dL) and ETCOc (1.61 ± 0.45 vs 2.02 ± 1.35 ppm, p = 0.0002) were different between the groups. About 36.6% of infants with TB/TcB ≥75th percentile had ETCOc ≥ 2.0 ppm. In the subcohort of infants with serial TB/TcB measurements (n = 76), 44.7% and 55.3% had TB/TcB<75th and ≥75th percentile, respectively. TB/TcB (5.28 ± 1.97 vs 9.53 ± 2.78 mg/dL), ETCOc (1.72 ± 0.48 vs 2.38 ± 1.89 ppm, p = 0.05) and TB ROR (0.011 ± 0.440 vs 0.172 ± 0.471 mg/dL/h) were different between the groups. The combined use of TB/TcB percentile risk assessments and ETCOc measurements can identify infants with haemolytic hyperbilirubinaemia. The addition of TB ROR can identify those infants with elimination disorders.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call