The spectrum of long bunches injected into the ring with RF switched o has been used in the SPS in the past to probe the longitudinal coupling impedance. After a large campaign of shielding of 800 inter-magnet vacuum ports in 1999 - 2001, the microwave instability threshold was significantly increased and the high-frequency spectrum of the beam became practically flat, apart from a prominent peak at around 1.4 GHz. As corresponding high-frequency impedance could potentially lead to microwave instability of high intensity bunches observed now at high energies in the SPS, a search of the source of this impedance was launched. Using a combination of impedance simulations and measurements, vacuum flanges that are present in a large quantity in the machine have been identified as a main source of impedance at this frequency. Particle simulations based on the SPS impedance model, which includes this previously unknown impedance, are able to reproduce the characteristics of the bunch spectrum and amplitude growth rates and hence, confirm that the impedance of the vacuum flanges is responsible for the observed spectral peak.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.