Abstract
17-4PH martensitic stainless steel samples were tested in a constant load equipment in a hot MgCl2 solution. Stress corrosion cracking was simultaneously monitored by electrochemical noise (EN) and acoustic emission (AE) techniques. During test corrosion mechanisms gradually evolve from localized pitting to stress corrosion cracking until final rupture. By combining the two monitoring techniques it was possible to distinguish between damage stages with a predominant electrochemical contribution and damage stages with a predominant mechanical contribution to crack propagation. The implementation of combined AE and EN measurements is a promising approach for reliable detection of damage phenomena in SCC promoting environment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.