Abstract
Non-specific uptake and retention of molecular targeted agents and heterogeneous tissue optical properties diminish the ability to differentiate between tumor and normal tissues using molecular targeted fluorescent agents. Paired-agent imaging (PAI) can increase the diagnostic ability to detect tumor tissue by mitigating these non-specific effects and providing true molecular contrast by co-administration of an untargeted control imaging agent with a targeted agent. This study evaluates the suitability of available clinically translatable untargeted agents for the translation of PAI in fluorescence-guided surgery using an affibody-based targeted imaging agent (ABY-029). DESIGN: Three untargeted agents that fluoresce near 700nm and exhibit good clinical safety profiles (methylene blue, IRDye 700DX, and IRDye 680LT) were tested in combination with the clinically tested IRDye 800CW-labeled anti-epidermal growth factor receptor (EGFR) affibody molecule, ABY-029 (eIND 122,681). Properties of the untargeted agent important for human use and integrity of PAI were tested: (1) plasma protein binding; (2) fluorescence signal linearity in in vitro whole blood dilution; (3) in vivo pharmacokinetic matching to targeted agent in negative control tissue; and (4) in vivo diagnostic accuracy of PAI vs single agent imaging (SAI) of ABY-029 alone in orthotopic oral head and neck squamous cell carcinomas. IRDye 680LT outperformed IRDye 700DX and methylene blue with the highest signal linearity (R2 = 0.9998 ± 0.0002, 0.9995 ± 0.0004, 0.91 ± 0.02, respectively), the highest fluorescence yield in whole blood at 1μM (104.42 ± 0.05, 103.68 ± 0.09, 101.9 ± 0.2, respectively), and the most closely matched ABY-029 pharmacokinetics in EGFR-negative tissues (binding potential error percentage = 0.31% ± 0.37%, 10.25% ± 1.30%, and 8.10% ± 5.37%, respectively). The diagnostic ability of PAI with ABY-029 and IRDye 680LT outperformed conventional SAI with an area-under-the-receiver-operating-characteristic curve (AUC) value of 0.964 vs. 0.854, and 0.978 vs. 0.925 in the Odyssey scanning system and Pearl wide field imaging system, respectively. PAI is a highly promising methodology for increasing detection of tumors in fluorescence-guided surgery. Although not yet clinically approved, IRDye 680LT demonstrates promise as an untargeted agent when paired with ABY-029. The clinical translation of PAI to maximize tumor excision, while minimizing normal tissue removal, could improve both patient survival and life quality.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have