We investigated prediction accuracy of an identification method using sensitivity analysis of CFD software developed by us named as “FlowDesigner”. We applied the identification method to predict the thermal conductivity of TIM with 0.1mm thickness set in between upper and lower base plates by using the measured temperature of targets located in the center of both upper and lower base plates. We clarified that the thermal conductivity of TIM was able to be predicted as 0.2W/m·K within prediction error band of ±10% under the condition of targets temperature measurement error was in between -1 and +0.8 K and heat flow ratio of in-plain direction against thickness direction was in between -1 and +0.8.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.