Abstract
Fentanyls abuse is a persistent international concern. New fentanyl derivatives are constantly appearing, circumventing national and international laws. In this study, laboratory degradation experiment with different conditions such as pH, light, temperature and oxygen availability were compared to improve the understanding of the fentanyls degradation pathways. Twelve major degradants of sufentanil and alfentanil were detected and identified together using UHPLC-QTOF-MS. A total of thirty nine fentanyls including twelve typical fentanyl new psychoactive substances, eighteen manufacturing process-related substances and nine key degradants of sufentanil and alfentanil were screened in 120 sewage water samples collected from 20 sewage water treatment plants chosen among 6 urban cities in east China from July to August in 2020 using a validated UHPLC-MS/MS method. Three fentanyls (fentanyl, sufentanil, alfentanil), seven degradants and six manufacturing process-related substances were found in the test samples. The study could provide a useful tool for the monitoring of the abuses, illegal manufacturing or pharmaceuticals related pollutions of fentanyls and their analogs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.