Abstract

Thin-layer chromatography (TLC) combined with photometry has been used successfully for the simultaneous determination of PETriN, DiPEHN, and TriPEON in PETN samples. The impurities are separated by one-dimensional TLC on Silica Gel G-Zn-sodium sulfanilate plates with an acetone-benzene mixed solvent. When the chromatogram is sprayed with N,N-dimethyl- i-naphthylamine (DMNA)-acetic acid reagent, the separated components are converted to a diazo dye to produce red spots on an off-white background. The intensities of the spots are measured by visible reflectance and are related to concentration by calibration curves. The standard deviations obtained in the analysis of various synthetic mixtures and authentic samples are less than 0.2%. Identification of the impurities is accomplished by their R G values, measured relative to PETN.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.