Abstract

The focus of this study is identification, isolation and characterization of a principal oxidation impurity of clopidogrel which ranged from 0.05 to 0.12% using high performance liquid chromatography. This impurity is considered as principal oxidation impurity as it is observed in oxidative degradation (stress) study. Preparative HPLC with Xterra MS C18 ODB column was used to isolate the impurity. The isolated impurity was co-injected with the sample containing impurities and found the retention time match of the spiked impurities. A thorough study was undertaken to characterize this impurity and based on their spectral data (UV, MS, MS n 1H/ 13C, DEPT and 2D NMR) the structure was characterized as 5-[1-(2-chlorophenyl)-2-methoxy-2-oxoethyl]-6,7-dihydrothieno[3,2- c]pyridin-5-ium with a molecular weight 320 amu.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.