Abstract

BackgroundIn acetabular fracture surgery, an infra-acetabular screw (IAS) is inserted from the anterior to the posterior column through the infra-acetabular corridor to stabilize both columns. Although the IAS is useful for increasing fixation strength, proper placement requires proficiency and often results in extraosseous screw penetration. The complex anatomy of the infra-acetabular corridor and difficult intraoperative detection of the ideal insertion point and angle make proper placement of the IAS challenging. This study aimed to detect the ideal insertion point and angle of the IAS based on anatomical landmarks that can be directly identified intraoperatively. MethodsWe retrospectively reviewed the pelvic CT of 50 adults who underwent serial slice CT imaging. The pelvic inlet plane (PIP), which contains the anterior border of both the sacroiliac joint and posterior superior edge of the pubic symphysis, was used as the reference plane for the pelvic coordinate system to simulate the ideal insertion of IAS. The distance from the posterior superior edge of the pubic symphysis to the ideal insertion point of the IAS (IAS distance) and the angle and length of the IAS that could be inserted from the ideal insertion point were measured. ResultsThe mean IAS distance was 61.0 ± 5.7 mm (57.6 ± 4.3 mm in men and 64.4 ± 4.9 mm in women). The mean angle between ideal IAS and yz-plane on the outlet view (α-angle) was 8.4 ± 6.6 ° (6.4 ± 5.6° in men and 10.5 ± 7.0° in women). The mean angle between ideal IAS and y-axis on the yz-plane (β-angle) was 86.5 ± 10.6 ° (86.0 ± 10.3° in men and 87.0 ± 10.9° in women). The length of IAS was 97.1 ± 4.7 mm in men and 89.2 ± 3.6 mm in women. ConclusionThe IAS ideal insertion point detected as a distance from the pubic symphysis may aid in the proper insertion of the IAS during surgery. The insertion angle was parallel or tilted 10 ° laterally to the longitudinal axis in the pelvic outlet plane and almost perpendicular to the PIP in the sagittal plane when inserted from the ideal insertion point.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.