Abstract

To evaluate the frequency of ice ball cracks on CT during cryoablation of renal tumors and assess the severity of hemorrhagic complications associated with this finding. Between March 2014 and March 2019, 130 patients underwent CT-guided cryoablation using cryoprobes with a diameter of 1.5mm for 138 renal tumors (mean diameter, 23.6mm; standard deviation [SD], 7.5; range, 8.3-43). Two blinded board-certified radiologists retrospectively reviewed the presence of cracks on CT obtained during the procedure. The incidence of major hemorrhage and changes in hemoglobin levels after cryoablation were examined. Factors influencing the appearance of ice ball cracks were assessed with multivariate analyses. Cracks were observed in 25 of the138 procedures (18%). Inter-reader reliabilities with kappa statistics were 0.90 and 0.84 for first and second freeze sessions, respectively. There were no major hemorrhagic events requiring blood transfusion or arterial embolization. Mean (± SD) decreases in hemoglobin levels between pre- and postoperative day 1 were 1.15 ± 0.86g/dl in the cracks group and 1.01 ± 0.80g/dl in the no cracks group with no significant difference (p = 0.14). Multivariate analyses identified a higher number of cryoprobes (odds ratio, 4.1; 95% confidence interval [CI] 1.7-11; p = 0.001) and no hydrodissection (odds ratio 6.7; 95% CI 2.1-28; p < 0.001) as factors associated with ice ball cracks. Ice ball cracks were frequently observed on CT during cryoablation for renal tumors and were seemingly self-limiting events requiring no intervention.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call