Abstract

This study introduces precast concrete beam–column connections comprised of composite beams, precast columns, and a monolithic joint core. The composite beams consist of U-shaped beams and floor slabs, leveraging the U-shaped beams for their lightweight nature, acceptable stiffness, and reduced demand for on-site support systems. To mitigate reinforcement congestion in the joint core, the precast connections incorporate large-diameter rebars (greater than 25 mm). This study conducted cyclic loading tests on four full-scale beam–column connections under 0.3 normalized compression, encompassing precast interior and exterior connections, along with two monolithic reference specimens, to investigate their behavior under seismic actions. The results revealed that all specimens exhibited bending failure at the beam ends, with minimal concrete deterioration observed in the joint core areas and columns. The hysteresis curves of the precast specimens and the monolithic connections exhibited a slight pinching effect. The strengths of the interior and exterior precast specimens were 13.3% and 7.8% lower than those of the reference monolithic connections, respectively. The ductility of interior precast connections and monolithic specimens stood at 2.36 and 2.23, respectively, indicating a negligible difference of less than 5%. Meanwhile, the positive and negative ductility of exterior precast connections were 3.06 and 2.34, which was approximately 8% lower than that of the reference connections. Furthermore, the stiffness degradation and energy dissipation capacity of the precast specimens aligned closely with the performance of the reference monolithic ones.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call