Abstract

Hysteresis loss in poloidal coils of the Large Helical Device (LHD) has been measured during single-pulse operation. The superconductors of the coils are Nb-Ti cable-in-conduit conductors (CICC) cooled by forced-flow supercritical helium. The loss was measured by monitoring the enthalpy increase of the helium coolant between the inlet and outlet. Although the hysteresis loss was extracted by extrapolating several data sets from pulse excitations with different sweep rates, the extrapolated loss was much larger than the estimation using the magnetic hysteresis of the conductor. The anomalous increase in the loss is likely due to inter-strand coupling loss with long time constants from the order of 10 to 1000 s. The calculations show that the additional coupling loss behaves like a hysteresis loss.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.