Abstract
A visible, hyperspectral imager using chromotomography CT) has been built, with the goal of extending the technology to spatially extended sources with quickly varying (> 10 Hz) features, such as bomb detonations and muzzle flashes. Even with a low dispersion, ~0.7 mrad/nm, direct vision prism with undeviated wavelength near λ = 548 nm , spectral resolution of better than Δ λ < 10 nm across the λ = 400 – 600 nm band is demonstrated with spatial resolution of better than 0.5 mm. The primary objective of this paper is to show empirically that the spatial and spectral resolution of data obtained by a simple CT instrument is unchanged in projection space and reconstructed object space.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of High Speed Electronics and Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.