Abstract

To evaluate the accuracy of technetium-99m sestamibi as a single agent in the detection and localization of hyperfunctioning parathyroid tissue in patients who underwent prior neck exploration or who otherwise are high surgical risks. Thirty-nine patients with hyperparathyroidism underwent 40 double-phase Tc-99m sestamibi studies. Histopathologic correlation was obtained for all studies. Thirty patients had solitary adenomas, and nine had hyperplastic glands. One developed recurrent hypercalcemia after five-gland resection and underwent repeat imaging and operation. Double-phase sestamibi imaging prospectively enabled localization of 46 (77%) of 60 abnormal glands. Twenty-eight (93%) of 30 adenomas were correctly localized, whereas 18 (60%) of 30 hyperplastic glands were localized. The overall specificity of the study was 98% with one false-positive study. Gland weight and vascularity were statistically significant predictors of uptake of sestamibi. Double-phase Tc-99m sestamibi imaging is a promising technique for localization of parathyroid adenomas in high-risk surgical patients. Localization of multiple hyperplastic glands remains a challenge.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.