Abstract

Hyperacute rejection is an early complication of transplantation, caused by the presence in the recipient of pre-formed donor-directed antibodies (Ab). We report a case of fatal early graft dysfunction after lung transplantation in a female recipient with no anti-HLA Ab detected before transplantation. Further immunologic studies revealed the presence, in the pre-transplant serum, of low-titer anti-HLA Ab directed against the donor's HLA, detectable only by flow-cytometry screening for panel-reactive antibodies. This observation emphasizes the importance of sensitive Ab detection in patients awaiting lung transplantation. Women should be specifically targeted for such sensitive Ab detection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.