Abstract

The purpose of the research is to assess the intra-environment indices in urban and rural secondary schools. In the course of special studies there was given the hygienic assessment of the climate, illumination and air quality of classrooms. In classrooms in rural schools microclimate indices were established to fail to meet hygienic requirements mainly on the temperature and humidity parameters. In rural schools, the temperature was decreased to 16-17 °C in 19.0 ± 8.6% of classrooms, humidity was elevated to 63.1% in 25.7 ± 7.4% of classrooms. Among urban schools the humidity in 49.6 ± 4.4% of classrooms reduced to 23.3 ± 0.3%, in 20.8 ± 5.4% of offices it was increased to 71.9 ± 0.9%. The coefficient of the natural illumination in rural schools has been reduced to 0.86-1.4% in 33.9 ± 14.2% of classrooms. In 25.1 ± 2.3% of classrooms in urban schools the level of natural light ratio was below the normative values and varied in the range of 0.32-1.3%. It is noted that in the offices of informatics natural light indices are significantly lower than in the classrooms for core subjects. The artificial lighting in urban schools was found to be lower than hygienic standards on the desks by 1.9 times, 2.2 times - at the board. There were obtained statistically significant handshaking health problems of urban schoolchildren due to intraenvironmental factors. The c dimate in surveyed gyms in rural schools is different in the low temperature and high humidity. The hygienic assessment of the air pollution classrooms’ medium was executed for a range of chemicals: formaldehyde, carbon monoxide, nitrogen dioxide, sulfur dioxide, particulate matter. Concentrations of formaldehyde; nitrogen dioxide, suspended solids in the air in classrooms in urban schools appeared to be higher than in rural schools. Carbon monoxide concentrations in classrooms in rural schools was found to exceed their values in urban schools. The air in classrooms of the one of the cities was found to be differed by a specific atmosphere for its chemical - hydrogen fluoride, in concentrations exceeding the maximum allowed concentration by 3-3.5 times.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.