Abstract

We report a case of hydrothorax after receiving intravenous (IV) contrast material by power injector through right subclavian central venous catheter (CVC) line. A 38-year-old woman presented to the local emergency department with hypotension after a pedestrian accident. After resuscitation, CVC was inserted into her right subclavian vein and fluid was administered well before computed tomography (CT) enhancement. Contrast-enhanced CT scan showed a large amount of extravasation of contrast material and fluid collection in the thoracic and pericardial cavities which was not shown in non-enhanced CT scan. During operation, vascular perforation was found in right subclavian vein. This case highlights that emergency physicians must keep in mind the possibility of vessel injury after CVC insertion and contrast material is preferably injected via peripheral IV access.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.