[1] The heat output and thermal regime of fast and intermediate spreading centers are strongly controlled by boundary layer processes between the hydrothermal system and the underlying crustal magma chamber (AMC), which remain to be fully understood. Here, we model the interactions between a shallow two-dimensional cellular hydrothermal system at temperatures <700°C, and a deeper AMC at temperatures up to 1200°C. We show that hydrothermal cooling can freeze the AMC in years to decades, unless melt injections occur on commensurate timescales. Moreover, the differential cooling between upflow and downflow zones can segment the AMC into mush and melt regions that alternate on sub-kilometric length scales. These predictions are consistent with along-axis variations in AMC roof depth observed in ophiolites and oceanic settings. In this respect, fine-scale geophysical investigations of the structure of AMCs may help constrain hydrothermal recharge locations associated with active hydrothermal sites.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.