Abstract
Assessment of the thermodynamics of SiC corrosion under light water reactor coolant environments suggests that silica formation is always expected in the range of applicable pH and potential. Autoclave testing of SiC-based materials in the absence of ionizing radiation was performed. The kinetics data from these tests, when compared with kinetics of silica dissolution in water and post-exposure characterization of SiC samples, suggest that oxidation of SiC to form silica is the rate-limiting step for recession of SiC in high temperature water. Oxygen activity in water was determined to play an important role in SiC recession kinetics. A simplified model of a power loop shows the effect of silica dissolution from the hot region (resembling fuel) and deposition in the cold regions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.