Abstract
The increasing use of chiral agrochemicals sold as racemic formulations raises concern for the negative impacts that inactive enantiomers can have on aquatic life and human health. The present work just focuses on the determination of ten chiral pesticides in river water samples by applying a ferrofluid-based microextraction followed by their stereoselective liquid chromatography analysis. To develop the ferrofluid, magnetite nanoparticles were prepared and coated with oleic acid and then dispersed in a hydrophobic natural deep eutectic solvent (NaDES), composed ofL-menthol and thymol (1:1). The stable colloidal dispersion was characterised by scanning electron microscopy, thermogravimetric analysis, energy-dispersive X-ray spectroscopy and attenuated total reflection Fourier transform infrared spectroscopy. The analyte microextraction from 5ml river samples was performed using 50µl of ferrofluid, while acidified acetonitrile (150µl) was used to break down the ferrofluid and solubilise the NaDES containing the analytes. All the extracts were analysed by high-performance liquid chromatography-tandem mass spectrometry. For each analyte, the baseline separation of isomers was achieved on a Lux i-Amylose-3 column (amylose tris(3-chloro-5-methylphenylcarbamate) working in reversed-phase mode; the combination with mass spectrometry detection allows the overall separation of 24 isomers (ten chiral analytes among which eight containing a single (one) chiral centre, one with two chiral centres and the last one existing in four stereoisomeric forms, due to the presence of two regioisomers with a chiral carbon) within 37min. The method showed very good figures of merit in terms of recoveries (77.7-97.5%), intra-day and inter-day precision (2.7-7.7% and 6.9-14.9%, respectively), limit of detection (0.01-0.35µg/L), limit of quantitation (0.03-1.20µg/L), linear dynamic range, and intra-day and inter-day accuracy (1.2-14.8% and 1.8-15.0%, respectively). The presented method was able to detect 14 out of 24 isomers at the preventive limit established by the Italian legislation for single pesticide (that for a chiral pesticide is the sum of all its isomers) in surface waters, set at 0.1µg/l. Finally, the method was evaluated using AGREEprep and ComplexGAPI metrics, compared with other ferrofluid-based methods, and applied to the analysis of water samples from two Italian rivers (the Nera River and the Tiber River), providing to be sustainable and reliable for the application to real river matrices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.