Abstract

To ensure the supply of raw materials for products of extreme importance in strategic sectors, the recovery of critical metals from secondary sources becomes increasingly urgent. Platinum group metals (PGMs), being rare and very valuable, fall into this demand, and the catalytic converters that contain them are recognized as one of the main sources. Hydrometallurgical processes have been proposed as an alternative to pyrometallurgical ones, with leaching and separation by solvent extraction being core operations in this type of processing. This article investigates these two operations, seeking to optimize conditions and propose new arrangements to improve them. Two different catalyst samples were considered in the experimental work. Leaching was carried out involving concentrated HCl solutions (with H2O2 as oxidant) and low liquid/solid ratios, seeking to maximize PGMs recovery, guaranteeing their high concentration in leachates and minimizing aluminum co-dissolution. Cerium leaching was also followed since this is a rare-earth metal with potential interest. Temperature, HCl concentration, liquid/solid ratio (L/S), time and particle size factors were evaluated, and the optimized conditions found were 11.6 mol L−1 HCl, 1%vol H2O2, 60 °C, L/S = 2 L kg−1 and 3 h, leading to PGM yields of 90–98% Pt, 99% Pd and 70–96% Rh, and leachate compositions of 0.41–0.78 g L−1 Pt, 1.6 g L−1 Pd, 0.062–0.066 g L−1 Rh, depending on the catalyst sample.For solvent extraction (SX), several commercial extractants dissolved/diluted in toluene were checked, firstly with a model solution, and then applied to the real spent auto-catalyst (SAC) leachates produced in-situ. The overall results showed that the most promising SX systems among those tested were Cyanex® 471X and Cyphos® IL 101. Cyanex® 471X allowed the quantitative extraction of Pd(II) and Fe(III), but the latter was conveniently scrubbed by water prior to Pd(II) stripping by an acidic thiourea solution. Pt(IV) and Pd(II) extraction values by Cyphos® IL 101 were very encouraging, as only Fe(III) and Zn(II) were appreciably co-extracted, however, scrubbing of the contaminating metals, and Pd(II) and Pt(IV) stripping, did not work. Hence, investigation to find proper scrubbing/stripping agents for Cyphos® IL 101 SX system, to recover PGMs from recycled SACs, is further needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.