Abstract

A study was conducted on H2S removal in a biotrickling filter packed with open-pore polyurethane foam. Thiobacillus denitrificans was used as inoculum and a mixed culture population was developed during the process. The inhibitory effect of sulphate concentration (1.8–16.8gL−1), pH (6.9–8.6), trickling liquid velocity (TLV, 9.1–22.8mh−1), H2S inlet concentration (20–157ppmv) and the empty bed residence time (EBRT, 9–57s) on the H2S removal efficiency (RE) were thoroughly investigated. An increase in pH from 6.9 to 8.5 led to a corresponding increase in H2S removal. In addition, an inhibitory effect of sulphate concentration was observed from 16.8gL−1 and the maximum elimination capacity was found to be 22gSm−3h−1 (RE 98%). The RE was constant (98.8±0.30%) for EBRT≥16s, but a decrease in the EBRT from 16 to 9s led to a corresponding decrease in RE from 98.2 to 89.6% for a TLV of 9.1mh−1 and from 97.9 to 94.9% for a TLV of 22.8mh−1 (inlet load of 11.0±0.2gSm−3h−1). The sulphur oxidation capacity in the biotrickling filter was not diminished by the presence of other bacteria.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.