Abstract

Two biotrickling filters were set up at two wastewater treatment plants (WWTP) in The Netherlands to investigate their effectiveness for treatment of odorous waste gases from different sources. One biotrickling filter was installed at Nieuwe Waterweg WWTP in Hook of Holland to study the hydrogen sulfide removal from headworks waste air. The other reactor was installed at Harnaschpolder WWTP (treating wastewater of the city of The Hague) to remove mercaptans and other organic compounds (odor) coming from the emissions of the anaerobic tanks of the biological nutrient removal (BNR) activated sludge. The performance of both units showed a stable and highly efficient operation under seasonal variations of load and temperature over nearly one year of monitoring. The Nieuwe Waterweg unit achieved removals of up to 99%, corresponding to a maximum daily average elimination capacity (EC) of 55.8 g H2S/m3/h at an empty bed residence time (EBRT) as short as 8.5 s. Odor reduction at the Harnaschpolder unit was 95% at an EBRT of 18.9 s, with average outlet concentration lower than the objective value which was established as 1000 European Odor Units (OUE/m3).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.