Abstract

After many years of passive autocatalytic recombiner (PAR) experimentation and analytical investigations, there are still gaps in the understanding of PAR behavior. For instance, PAR performance under severe accident conditions including issues related to low oxygen content, presence of carbon monoxide, and reactive or non-reactive aerosols still require examination.Following the closure of the large-scale hydrogen test facilities at AECL’s Whiteshell Laboratories (WL), a new Hydrogen Safety Test Facility (HSTF) has been commissioned at Chalk River Laboratories (CRL) to continue the efforts to understand PARs and their operation in various accident scenarios. The HSTF is a spherical pressure vessel with an internal volume of 0.25 m3. This paper presents the experiments performed at the HSTF, investigating the scaling of a PAR under varying concentrations of H2, and steam as well as the effects of initial gas temperature and pressure. The experimental data from the HSTF (0.25 m3) will be compared with the data obtained in the large-scale facilities (6.6 m3 and 60 m3) to establish a scaling factor for the HSTF with a reasonable fit over the range of conditions tested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.