Abstract
Abstract The vast majority of experimental techniques used for the measurements of hydrogen permeability through metallic membranes whose one or both surfaces are covered with a thin Pd film is based on the assumption that a ratio of film-to-membrane thickness is small enough to cause hydrogen flow to be independent of the Pd film thickness. In an attempt to verify this assumption, we have measured the hydrogen flow through the Pd33Ni52Si15 amorphous membrane covered with Pd film of 10, 20, and 30 nm in thickness. Contrary to our expectations, we have found a dramatic decrease in hydrogen flow with the increase in Pd film thickness. Our findings are discussed in terms of potential barrier between the two different phases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.