Abstract

Laser-induced breakdown spectroscopy is a promising method for rapidly measuring hydrogen and its isotopes, critical to a wide range of disciplines (e.g. nuclear energy, hydrogen storage). However, line broadening can hinder the ability to detect finely spaced isotopic shifts. Here, the effects of varying plasma generation conditions (nanosecond versus femtosecond laser ablation) and ambient environments (argon versus helium gas) on spectral features generated from Zircaloy-4 targets with varying hydrogen isotopic compositions were studied. Time-resolved 2D spectral imaging was employed to detail the spatial distribution of species throughout plasma evolution. Results highlight that hydrogen and deuterium isotopic shifts can be measured with minimal spectral broadening in a ∼ 10 Torr helium gas environment using ultrafast laser-produced plasmas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.