Abstract

Gas chromatographic separation of hydrogen isotopes on the combined column of 5 Å molecular sieve and Al 2 O 3 at cryogenics has been investigated. This paper described the procedures for preparation and operation of the chromatographic combined separation column and discussed the separation effects. Experimental results showed that the purity of deuterium reached above 99.9% through the combined separation column. This system possesses some advantages such as simple construction, low operation cost, a less investment and so on. It is promising for engineering applications, particularly in some laboratories and departments where a small amount of high purity species of hydrogen isotope is required. Not only it is used for the separation of hydrogen and deuterium, but also used for the separation of deuterium and tritium.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call