Abstract

ABSTRACTChromatographic separation of hydrogen isotopes, protium and deuterium, was carried out experimentally using a four-column Pd bed system. The system was operated under the conditions of atmospheric hydrogen pressure and swing of column temperature of 303 K to 473 K. Maximum deuterium enrichment ratio defined as the ratio of the deuterium concentration in product to that in feed was around 100 independent of the deuterium concentration. The deuterium recovery ratio was more than 0.5. Effluent curves were analyzed by the numerical simulation by the plate model. Close agreement was obtained between experiment and analysis. High enrichment of deuterium was also successfully achieved by frontal chromatography using a comparatively large column.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.