Abstract

The ASDEX upgrade vacuum vessel is equipped with 14 turbo molecular pumps (TMPs) and a cryo pump (CP). The CP is cooled with boiling helium (He). To obtain similar conditions with the CP for hydrogen (H 2) and deuterium (D 2) pumping a lower helium panel temperature (T HP) is required in the case of H 2. This is achieved by reducing the He boiling pressure (p b) and thus the He boiling temperature (T b) via pump down of the He cryostat. The requirements are predicted by computations and verified experimentally for this case. By raising the cryostat pressure above ambient, the prediction of the H 2 end pressure (p eH2) of the CP could be compared with measurements in the range 5×10 −7<p eH2 (mbar)<5×10 −4. The beneficial effect of argon frosting for helium pumping is only shown experimentally.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.