Abstract

Slow strain rate testing (SSRT) was carried out on over aged 7010 Al-alloy in laboratory air, glycerin and 3.5 wt.% NaCl solution with and without cathodic charging to study the hydrogen embrittlement susceptibility of the alloy in over aged condition. It was found that the over aged alloy exhibited high resistance to stress corrosion cracking (SCC) than hydrogen embrittlement (HE). The high SCC resistance is due to the modification in the grain boundary precipitate morphology and chemistry due to over aging, however it is suggested that the dislocations in the alloy are not completed annealed during over aging to arrest HE.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.