Abstract

Coated coils for endovascular treatment of cerebral aneurysm were developed to reduce recurrence and retreatment rates, and have been in clinical use for 8-9 years without robust evidence to determine their efficacy. We assessed the efficacy and safety of hydrogel-coated coils. This randomised trial was undertaken in 24 centres in seven countries. Patients aged 18-75 years with a previously untreated ruptured or unruptured cerebral aneurysm of 2-25 mm in maximum diameter were randomly allocated (1:1) to aneurysm coiling with either hydrogel-coated coils or standard bare platinum coils (control). Randomisation was done with a computer-generated sequence, stratified by aneurysm size, shape, and dome-to-neck ratio; intention to use assist device; and by region. Participants and those assessing outcomes were masked to allocation. Analysis was by modified intention to treat (excluding missing data). Primary outcome was a composite of angiographic and clinical outcomes at 18-month follow-up. We also did prespecified subgroup analyses of characteristics likely to be relevant to angiographic outcome. This study is registered as an International Standard Randomised Controlled Trial, number ISRCTN30531382. 249 patients were allocated to the hydrogel coil group and 250 to the control group. In 44 of 467 patients for whom an 18-month composite primary outcome was unavailable, 6-month angiographic results were used. 70 (28%) patients in the hydrogel group and 90 (36%) control patients had an adverse composite primary outcome, giving an absolute reduction in the proportion of adverse composite primary outcomes with hydrogel of 7·0% (95% CI -1·6 to 15·5), odds ratio (OR) 0·73 (0·49-1·1, p=0·13). In a prespecified subgroup analysis in recently ruptured aneurysms, there were more adverse composite primary outcomes in the control group than in the hydrogel group-OR 2·08 (1·24-3·46, p=0·014). There were 8·6% fewer major angiographic recurrences in patients allocated to hydrogel coils-OR 0·7 (0·4-1·0, p=0·049). There were five cases of unexplained hydrocephalus in not-recently-ruptured aneurysms in the hydrogel coil group and one case in the control group. Whether use of hydrogel coils reduces late aneurysm rupture or improves long-term clinical outcome is not clear, but our results indicate that their use lowers major recurrence. MicroVention Inc.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.