Abstract
AbstractHydrodynamic and mass transfer data in Soltrol‐130 (a mixture of C9+ iso‐paraffins) were measured in a 0.305 m diameter bubble column. The gas holdup structure (i.e., the contributions to holdup from the small and large bubble fractions of the dispersion) for this hydrocarbon liquid in the churn turbulent flow regime was analyzed using the dynamic gas disengagement technique. The validity of the assumption of axially uniform gas holdup structure was checked. Literature correlations were found inadequate to explain the observed gas holdup and the volumetric mass transfer coefficients for Soltrol‐130. The volumetric mass transfer coefficient per unit volume of large bubbles is shown to be independent of superficial gas velocity for the fully developed churn turbulent regime. The present hydrodynamic and mass transfer data in the churn turbulent regime should be useful in the design and scale‐up of bubble columns used in organic process industries.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.